Sælges: Solgt: Hitachi Deskstar 500 GB

Harddiske d.  07. juli. 2015, skrevet af Had
Vist: 634 gange.

Had
 
Elitebruger
Tilføjet:
07-07-2015 09:18:18
Svar/Indlæg:
139 / 51
Omdømme:
1 / 0


Postnr./by
7080 Børkop
Stort set ubrugt, været aktiv under 600 timer.

Sælges for HBO 150 kr.

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-37-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar P7K500
Device Model: Hitachi HDP725050GLA360
Serial Number: XXXXXXXXXXXXXXXX
Firmware Version: GM4OA57A
User Capacity: 500.107.862.016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS T13/1699-D revision 4
SATA Version is: SATA 2.6, 3.0 Gb/s
Local Time is: Tue Jul 7 00:31:56 2015 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x85) Offline data collection activity
was aborted by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 7890) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 131) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 096 016 Pre-fail Always - 0
2 Throughput_Performance 0x0005 133 100 054 Pre-fail Offline - 139
3 Spin_Up_Time 0x0007 137 100 024 Pre-fail Always - 286 (Average 275)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 560
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 131 100 020 Pre-fail Offline - 29
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 540
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 394
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 560
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 560
194 Temperature_Celsius 0x0002 136 113 000 Old_age Always - 44 (Min/Max 17/53)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 539 -
# 2 Short offline Completed without error 00% 514 -
# 3 Short offline Completed without error 00% 1 -

SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


Tråden blev redigeret 1 gang, sidst af Had d. 28-07-2015 16:35:26.
Had
 
Elitebruger
Tilføjet:
15-07-2015 13:43:50
Svar/Indlæg:
139 / 51
Omdømme:
1 / 0
Bump
HBO 100


Jexzy
 
Ny Bruger
Tilføjet:
28-07-2015 12:57:35
Svar/Indlæg:
2 / 0
Omdømme:
0 / 0
Hvor meget tænker du hvis pp? Køber den gerne hvis under 200.


Had
 
Elitebruger
Tilføjet:
28-07-2015 16:35:15
Svar/Indlæg:
139 / 51
Omdømme:
1 / 0
Hov, beklager. Er solgt